AIFIELD · Devices

Impinging jet cooler

An air jet from a nozzle cools a hot spot at the bottom of a solid disc.

Heat

Design model, not yet built.

A nozzle above a solid disc in AIFIELD CAD, the disc coloured by its solved temperature with the hot spot at the centre; the arrow marks the 20 mm nozzle stand-off.
Temperature of the disc, 297.4 to 316.3 K. The arrow marks the nozzle stand-off, 20 mm above the disc.

The result

What the solve shows.

Hot spot
Peak 316.3 K with 2 W into the disc.
Jet
1.84 g/s of air at Mach 0.23 from the nozzle.
Cooling
Average heat transfer 393 W/(m²·K) over the disc.
Mesh check
The peak moves by 0.0007 K from 640 to 2560 cells.

What was solved

The physics behind it.

Nozzle
The air flow and speed leaving an ideal nozzle.
Cooling
How strongly the jet cools the disc, from a published correlation.
Heat
Heat conduction through the disc, all 2 W leaving at the jet face.

Models behind the numbers: An ideal gas nozzle model, a published impingement correlation and a heat-conduction model of the disc. The air flow itself is not solved.

Design your own device like this.

We're opening AIFIELD to a small group of device designers in early 2027.